Adalio, a Polish manufacturer of thermal insulation coatings

Warmer in winter. Cooler in summer. Without replacing windows, roof coverings, insulation or façades.

Innovative thermal insulation and waterproofing coatings for cost-effective green construction. Our solutions make it easier to upgrade existing buildings and complement the building envelope in new developments.

The choice starts with the surface.

Explore Adalio product lines: versatile IzolPLUS coatings for opaque surfaces and transparent IzolGLASS solutions for glazing and skylights.

Energy balance for transparent and opaque surfaces. How IzolGLASS and IzolPLUS interact with energy at the surface. The diagrams show what passes through glazing, what is blocked at Active TT and what is reflected by an IzolPLUS coating. The notes below describe the winter mechanism.
Transparent surface

IzolGLASS

Glazing and glass façades
Transparent surface

Glass with IzolGLASS film

The Active TT nanocoating works on the outer face of the glass.

Outside Active TT Glass Interior
Glass with IzolGLASS film about 70% of visible light passes through the glazing, >93% of IR is blocked and >99% of UV is blocked at the Active TT layer. SOLAR RADIATION VL ABOUT 70% LIGHT INSIDE IR >93% IR BLOCKED South variant - North: >60% UV >99% BLOCKED reported values - data sheet v6 [S031] - Springer 2024 [S001]
of visible light passes throughbrightness and transparency retained
about 70%
of IR blockedPołudnie: >93%; Północ: >60%
>93%
of UV blockedActive TT Północ and Active TT Południe
>99%

reported values - data sheet v6 [S031] - Springer 2024 [S001]

In winter, the same mechanism limits radiative heat loss from the interior.

Transparent solutions for existing windows, skylights and glass façades. Active TT Północ and Active TT Południe films are selected for the glazing and expected performance.

How it works

Active TT technology works selectively with the spectrum while the film maintains the transparency required of glazing.

Opaque surface

IzolPLUS

Roofs, walls and installations
Opaque surface

Wall with IzolPLUS coating

The microsphere coating reflects energy before it enters the envelope.

Outside IzolPLUS coating Envelope
Wall with IzolPLUS coating 90-93% of thermal radiation is reflected at the IzolPLUS coating. Its declared thermal conductivity is 0.00079 W/m·K. SOLAR RADIATION 90-93% REFLECTED before energy enters the envelope λ λ 0.00079 W/m·K reported values [S172] - λ: MDPI Energies 2022 [S002]
of thermal radiation reflectedlimits surface heat-up
90-93%
Thermal conductivity
λ 0.00079 W/m·K

reported values [S172] - λ: MDPI Energies 2022 [S002]

In winter, the coating limits radiative heat loss from the envelope.

A family of coatings selected for the substrate and use. It covers façades, interiors, roofs and industrial installations, together with products that prepare and complete the system.

How it works

The coating works at the face of a wall, roof or installation, limiting heat transfer and the effect of thermal radiation.

Technology developed by the manufacturer and verified through testing.

The product tree shows the relationship between Adalio, its two product lines, technologies and the products selected for specific surfaces.

See research and documentation
Manufacturer Adalio Thermal insulation coatings
Opaque line

IzolPLUS

Walls, roofs and installations

  • Termo-Fasada
  • Termo-Wnętrze
  • Bitum
  • Grunt Uniwersalny
  • Tynk termoizolacyjny
  • Termo Stop
Transparent line

IzolGLASS

Glazing and glass façades

Active TT proprietary nanocoating technology
  • Active TT Północ film
  • Active TT Południe film

Technology developed in Poland

We develop the technology and formulations in Poland and commission manufacturing in Europe.

Adalio / asset-light manufacturing model

Patent and publications

IzolPLUS is described in Energies, and Active TT film in JTAC. IzolPLUS technology is protected by patent EP3594291A1.

Peer-reviewed publications and Espacenet

Before-and-after measurement

Thermal imaging documents surface conditions before and after application.

Measurement documentation from completed projects

Less stripping and demolition

A thin application can limit demolition work. We define the scope around the surface and building conditions.

On the same roof: 17-21°C and 63°C.

On 5 June 2023, two areas of the AAM Driveline factory roof in Świdnica were measured. The area coated with IzolPLUS Bitum measured 17-21°C, while an uncoated area measured 63°C. The air temperature was 23°C.

Source: one comparative thermal imaging measurement, testo 872s camera.

See the full case study
05.06.2023 23°C air testo 872s
Surface with IzolPLUS Bitum17-21°C
Uncoated surface63°C

The same roof. The same day. One measurement.

Selected projects Buildings, industry, district heating and heritage sites.
AAM DrivelineGPEC GdańskSEC SzczecinŁazarski UniversityStatistics Poland ArchiveParish in Łapy

Choose the right way to work with Adalio.

A home project, a larger facility and a local sales network each require a different starting point. Choose the path that matches your role.

Become a distributor

Build your local Adalio offer.

Add coatings and glazing solutions to your portfolio with product and implementation support.

Discuss distribution

Business client

Plan a solution for your building or process.

Discuss roofs, façades, glazing or industrial installations with a technical advisor.

Discuss a business project