Adalio case studies

Measurements and applications from real buildings.

Measurements describe surface temperature under defined conditions. Project records show where IzolPLUS and IzolGLASS have been used and link to the available evidence.

Modern building with different types of envelope surfaces
Evidence index / measurement, document, application
17-21°C Bitum-coated roof area AAM Driveline, 5 June 2023
63°C uncoated area of the same roof Testo 872s thermal imaging
6 published English case studies current case study library

Project index

Find a building or installation similar to yours.

A measurement and an application record are different forms of evidence. Each project page states the available source and conditions.

Heritage / Nadułki, Poland

Heritage manor house (18th-19th century) - Nadułki

Application of IzolGLASS Active TT film on the window glazing of a heritage manor house. Window joinery replacement ruled out by conservation requirements. Contractor and owner - Sławomir Włoszczak, president of BOTI-CEL.

Reference tile+9.5°CSummer temperature-5 to -6°C
View the case study

Residential / Wałbrzych, Daszyńskiego 25, Poland

Roof of a multifamily building - Wałbrzych

Revitalization of roof covering under public procurement. Thin-Layer Hydro-Thermal Insulation System - 2 layers of compound plus 2 layers of IzolPLUS Bitum paint on roofing felt.

Additional thermal resistance R6.4 m²·K/WPackage U-value< 0.15 W/m²K
View the case study

Industry / District heating / Gdańsk / Szczecin, Poland / 2024

District heating infrastructure - GPEC Gdańsk and SEC Szczecin

IzolPLUS at GPEC Gdańsk heating substations and an SEC Szczecin district heating chamber. Application scope and estimated heat loss reduction for the analysed SEC chamber.

Estimated heat loss reduction in the analysed SEC chamber> 85%
View the case study

Heritage / Łomża, Plac Niepodległości 10, Poland

Heritage townhouse from 1898 - Łomża

IzolPLUS coating on both sides (Termo-Fasada on the front facade, Termo-Wnętrze inside) without ETICS and without replacing joinery. Modernization confirmed by the Heritage Conservator.

Floor-ceiling difference≤ 2°CFreezing-throughDisappeared
View the case study

Education / Warsaw, Poland

Łazarski University - IzolPLUS thermal modernization

Comprehensive improvement of the energy efficiency of the Łazarski University building in Warsaw using IzolPLUS thermoreflective paints on facades, roofs and internal surfaces.

ProductIzolPLUSScopeFacade, roofs, interiors
View the case study

Heritage / Łapy, Podlaskie Voivodeship, Poland

Holy Cross Parish Church - Łapy

Full IzolPLUS system during a major renovation of a heritage church - Termo-Fasada and Termo-Wnętrze paints plus thermal insulation compound. Over 3,000 litres of material. Window joinery replacement ruled out by conservation requirements.

Energy bills-25 to -30%Excess moistureEliminated
View the case study

Evidence standard

What should a complete case study contain?

  • 01
    Problem

    The situation before the work, without figures unsupported by a measurement or document.

  • 02
    Scope

    The product, surface and relevant application conditions.

  • 03
    Measurement

    Values, units, date, ambient temperature, method and equipment.

  • 04
    Meaning

    A benefit that follows directly from the measurement or a documented client observation.

Building assessment

Discuss a measurement for your building or installation.

Describe the surface, problem and location. We will identify the data required for an assessment and a suitable way to document the result.
Book an initial assessment